A Guide to EEG Artifacts: Types and Causes

EEG

Introduction

Electroencephalography (EEG) is a widely used neurophysiological technique that records electrical activity in the brain through electrodes placed on the scalp. It plays a crucial role in diagnosing neurological disorders, studying cognitive processes, and advancing brain-computer interface (BCI) technologies. However, one of the major challenges in EEG analysis is the presence of artifacts—unwanted signals that distort or obscure true brain activity.

Artifacts in EEG recordings can arise from various sources, including physiological factors (such as eye movements, muscle contractions, and heartbeats) and non-physiological interferences (such as electrical noise, poor electrode contact, and movement-related disturbances). These artifacts can significantly impact the accuracy of EEG data interpretation, leading to misclassification of brain states, incorrect medical diagnoses, or unreliable results in scientific research.

To ensure high-quality EEG recordings, researchers and clinicians must be able to identify, understand, and mitigate these artifacts. Some artifacts can be minimized through proper preparation, such as ensuring good electrode placement, while others require advanced signal processing techniques for removal.

In this article, we will explore the various types of EEG artifacts, their causes, and the methods used to detect and manage them. By gaining a deeper understanding of EEG artifacts, we can enhance the accuracy and reliability of EEG-based studies and applications.



Types of EEG Artifacts and Their Examples

1. Physiological Artifacts (Originating from the Body)

Physiological artifacts are caused by the body’s natural activities, such as eye movements, muscle contractions, or heartbeats, which interfere with EEG signals.

a) Eye Movement Artifacts (EOG Artifacts)

  • The eyes act as dipoles, generating electrical activity that can be picked up by EEG electrodes.
  • Examples: Blinking, saccadic (rapid) eye movements, and slow eye rolling.
  • Effect on EEG: Appears as large, slow waves, especially in frontal electrodes.

b) Muscle Artifacts (EMG Artifacts)

  • Muscle contractions generate high-frequency electrical activity that can overlap with EEG signals.
  • Examples: Jaw clenching, facial expressions, chewing, and neck movements.
  • Effect on EEG: Produces high-frequency noise (20–300 Hz), mostly in temporal and frontal areas.

c) Cardiac Artifacts (ECG Artifacts)

  • The electrical activity of the heart can sometimes be detected in EEG recordings.
  • Examples: Heartbeat-related noise, common when electrodes are near blood vessels.
  • Effect on EEG: Regular, rhythmic waveforms, often seen in posterior channels.

d) Respiratory Artifacts

  • Breathing can cause slow fluctuations in EEG signals due to movement-related shifts.
  • Examples: Deep breathing, holding breath, or irregular breathing patterns.
  • Effect on EEG: Slow, low-frequency drifts in the signal, affecting baseline stability.

e) Sweat Artifacts

  • Sweat creates changes in skin conductivity, leading to slow signal drifts.
  • Examples: Excessive sweating during long EEG sessions.
  • Effect on EEG: Low-frequency noise, similar to electrode drift.


2. Non-Physiological (Technical/Environmental) Artifacts

These artifacts result from external factors such as faulty equipment, environmental interference, or improper electrode placement.

a) Electrode Artifacts

  • Poor electrode contact or drying gel can cause unstable signals.
  • Examples: Loose or detached electrodes, corroded connectors, or excessive electrode movement.
  • Effect on EEG: Sudden signal jumps, high impedance noise, or complete signal loss.

b) Power Line Interference

  • Electrical devices generate 50/60 Hz noise, affecting EEG recordings.
  • Examples: Nearby power sources, faulty grounding, or poor shielding of equipment.
  • Effect on EEG: Continuous sinusoidal wave at 50/60 Hz, seen across all channels.

c) Movement Artifacts

  • Physical movements can cause mechanical shifts in electrodes and cables.
  • Examples: Head movements, body repositioning, or touching the electrodes.
  • Effect on EEG: Sudden, irregular spikes and baseline shifts.

d) Electromagnetic Interference (EMI)

  • External electronic devices can introduce noise into EEG signals.
  • Examples: Mobile phones, Wi-Fi signals, fluorescent lights, and nearby medical equipment.
  • Effect on EEG: High-frequency noise, resembling a distorted signal.

Why Do We Need to Reduce EEG Artifacts?

  1. Misinterpretation of Brain Activity: Artifacts can mimic or obscure real neural signals, leading to incorrect conclusions about brain function.
  2. False Diagnoses in Clinical Applications: EEG is widely used in diagnosing neurological conditions such as epilepsy, sleep disorders, and brain injuries. Unfiltered artifacts may cause false positives or negatives, affecting medical decisions.
  3. Reduced Effectiveness of Brain-Computer Interfaces (BCIs): BCIs rely on clean EEG data to translate brain activity into commands. Artifacts can decrease their accuracy, leading to system failures.
  4. Compromised Research Data: Inaccurate EEG data due to artifacts can undermine the validity of scientific studies, making results unreliable.

EEG artifacts can significantly impact the accuracy and reliability of brain signal recordings. If these unwanted signals are not properly identified and removed, they can lead to several issues:

For these reasons, proper identification and removal of EEG artifacts are essential for maintaining data quality and ensuring accurate interpretation in both clinical and research settings.

Methods to Reduce EEG Artifacts

1. Reducing Physiological Artifacts

a) Eye Movement Artifacts (EOG Artifacts)

Eye movements, including blinks, saccades, and rolling, create strong electrical signals that can distort EEG recordings, particularly in frontal electrodes.

  • Electrode Placement Optimization: Position reference electrodes further from the eyes, such as on the mastoid or behind the ears, to minimize contamination.
  • Participant Instructions: Ask the subject to focus on a fixed point and minimize blinking during critical recording periods.
  • Signal Processing Techniques: Use Independent Component Analysis (ICA) or regression-based methods to remove eye-related activity from EEG signals.

b) Muscle Artifacts (EMG Artifacts)

Muscle contractions generate high-frequency electrical noise that can interfere with EEG readings, particularly in the temporal and frontal regions.

  • Relaxation and Preparation: Encourage participants to relax their facial muscles and avoid excessive jaw clenching or frowning.
  • Reducing Movement During Recording: Ask participants to remain as still as possible and avoid unnecessary head or body movement.
  • Filtering Techniques: Apply high-pass filters above 20 Hz to reduce muscle-related noise while preserving brain activity.

c) Cardiac Artifacts (ECG Artifacts)

The electrical activity of the heart can sometimes be picked up by EEG electrodes, especially when placed near major blood vessels.

  • Strategic Electrode Placement: Position reference electrodes away from the neck and major arteries to reduce interference.
  • Signal Processing Methods: Use ICA, adaptive filtering, or template subtraction techniques to remove heartbeat-related noise.

d) Respiratory Artifacts

Breathing-induced movements can cause slow fluctuations in EEG signals, affecting baseline stability.

  • Breath Control Awareness: Instruct subjects to maintain steady, relaxed breathing to reduce variability.
  • Post-Processing Corrections: Use regression-based approaches or ICA to remove respiratory artifacts from EEG data.

e) Sweat Artifacts

Excessive sweating increases skin impedance, leading to slow signal drifts and instability.

  • Maintaining an Optimal Environment: Keep the recording room at a cool temperature to prevent excessive sweating.
  • Ensuring Proper Conductivity: Apply sufficient conductive gel to maintain stable electrode contact throughout the recording session.

2. Reducing Non-Physiological (Technical/Environmental) Artifacts

a) Electrode Artifacts

Loose electrodes, poor skin contact, or drying conductive gel can lead to unstable signals and sudden jumps in EEG recordings.

  • Proper Electrode Preparation: Clean the scalp to remove oil and dirt before attaching electrodes.
  • Securing Electrodes: Use medical-grade adhesive or elastic caps to keep electrodes in place.
  • Routine Equipment Checks: Regularly inspect electrodes, wires, and amplifiers to ensure proper functionality.

b) Power Line Interference

Electrical devices and power lines introduce 50/60 Hz noise, which can contaminate EEG signals.

  • Minimizing Electrical Exposure: Conduct recordings in a dedicated EEG lab away from high-power electrical sources.
  • Using Shielded Cables: Shielded and grounded EEG cables help prevent AC interference.
  • Applying Notch Filters: A 50/60 Hz notch filter can remove power line noise from EEG signals.

c) Movement Artifacts

Body movements cause mechanical shifts in electrodes and cables, leading to significant distortions in EEG recordings.

  • Encouraging Stillness: Instruct subjects to remain as still as possible during data collection.
  • Providing Physical Support: Use a comfortable setup with headrests or chin supports to reduce involuntary head movements.
  • Identifying and Removing Affected Segments: Detect and exclude motion-contaminated data using automated artifact detection algorithms.

d) Electromagnetic Interference (EMI)

External electronic devices generate electromagnetic waves that can interfere with EEG signals.

  • Choosing an EMI-Free Environment: Conduct EEG recordings in a shielded room with minimal external interference.
  • Turning Off Nearby Electronics: Switch off mobile phones, Wi-Fi routers, and other wireless devices during data collection.
  • Using a Faraday Cage: For highly sensitive recordings, an enclosed metal shield (Faraday cage) can block external electromagnetic interference.


Conclusion

EEG artifacts are a common challenge in neurophysiological recordings, but they do not need to compromise the quality and reliability of EEG data. Understanding the different types of artifacts, whether physiological or non-physiological, is the first step toward improving the accuracy of EEG measurements. Physiological artifacts, such as those caused by eye movements, muscle contractions, and heartbeats, originate from within the body, while non-physiological artifacts result from external factors like equipment malfunctions, environmental noise, and movement.

Effective artifact management is crucial for obtaining clean EEG signals, as these artifacts can obscure or distort the neural activity we aim to study. In clinical settings, where EEG is used for diagnosing conditions such as epilepsy, sleep disorders, or neurological impairments, the presence of uncorrected artifacts can lead to misinterpretation of results, ultimately affecting patient care. In research, artifacts can undermine the validity of findings, making it challenging to draw accurate conclusions or replicate studies.

To reduce the impact of artifacts, it is essential to implement strategies such as optimal electrode placement, proper participant instructions, and the use of advanced signal processing techniques like Independent Component Analysis (ICA) or adaptive filtering. These methods allow researchers to isolate and remove unwanted signals without compromising the integrity of the brain activity they are studying. Additionally, controlling the recording environment by minimizing electrical interference and ensuring electrode stability is essential for maintaining signal clarity.

Furthermore, it is important to develop and adopt best practices that account for the various types of artifacts. With proper training and awareness, clinicians and researchers can recognize artifacts as they occur and take swift action to minimize their impact. Regular calibration of equipment, routine quality checks of electrodes, and the use of appropriate filters during post-processing can significantly enhance the overall data quality.

In conclusion, reducing EEG artifacts is not just a technical necessity but also a critical component in ensuring the accuracy of both clinical assessments and scientific research. By addressing artifact-related challenges, we enable more precise measurement of brain activity, which leads to better diagnostic outcomes, more reliable research findings, and ultimately, a deeper understanding of the brain’s complex functions. With the continuous advancements in EEG technology and signal processing techniques, we can look forward to even more accurate, artifact-free recordings that further enhance the field of neuroscience and its practical applications.